Close
  • Shopping Cart 0
    You have no items in your shopping cart.
  • Register
  • Log in
  • Wishlist
  • Shopping cart
inverter.com
0
Close
  • Power Inverter
    • Back
    • 12v Inverter
    • 24v Inverter
    • 48v Inverter
    • Car inverter
  • Sine Wave Inverter
    • Back
    • 12v Pure Sine Wave Inverter
    • 24v Pure Sine Wave Inverter
    • 48v Pure Sine Wave Inverter
    • Pure Sine Wave UPS Inverter
  • Solar Inverter
    • Back
    • On Grid Inverter
    • Off Grid Inverter
      • Back
      • Split Phase Off Grid Inverter
    • Micro Inverter
    • Solar Pump Inverter
    • Hybrid Solar Inverter
  • Frequency Inverter
    • Back
    • Single Phase Output Inverter
    • Single to Three Phase Inverter
    • Three Phase Inverter
    • 120v Input Inverter
  • Solar Products
    • Back
    • Solar Charge Controller
      • Back
      • MPPT Solar Charge Controller
      • PWM Solar Charge Controller
    • Solar Water Pump
    • Solar Generator
    • Solar Connector
    • Portable Solar Panel
    • Voltage Converter
    • Centrifugal Pump
      • Back
      • Horizontal Centrifugal Pump
      • Vertical Centrifugal Pump
    • Solar Light
      • Back
      • Solar Flood Light
      • Solar Inground Light
      • Solar Flashlight
  • Generator
    • Back
    • Inverter Generator
    • Wind Turbine
      • Back
      • Horizontal Axis Wind Turbine
      • Vertical Axis Wind Turbine
    • Wind Turbine Charge Controller
Close
  • Home /
  • Solar Products /
  • Centrifugal Pump /
  • Horizontal Centrifugal Pump /
  • 20 hp Horizontal Centrifugal Pump
20 hp Horizontal Centrifugal Pump

20 hp Horizontal Centrifugal Pump

$4,197.68
| 1 review(s) | Add your review
20 hp horizontal centrifugal pump for sale, has optional input voltage AC 220V/230V/340V, 380V/400V/415V, 440V/460V to 480V, optional input frequency 50Hz/60Hz, maximum flow 32.5m3/h (143 gpm), maximum head 82m (269ft) and same diameter of inlet and outlet 65mm (2-1/2 inch), can be used for high-rise building pressurized water supply, HVAC & refrigeration water circulation, cool water pressurization in air conditioner, etc.
Free shipping
Delivery date: 6-12 days
SKU: ATO-HCP-015KW
*
*
increase decrease
  • Overview
  • Manual
  • Reviews
Overview

20 hp horizontal centrifugal pump with 32.5m3/h maximum flow, 82m maximum head, and 65mm diameter of inlet and outlet.

Features:

  1. The centrifugal pump has a horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. There is no need to dismantle the pipeline system, just lift off the conjunction flat nut of the vertical pump. Then, all the rotor parts can be taken out.
  3. A horizontal centrifugal pump can operate in series and parallel connection according to the requirements of flow and head.
  4. The installation angle of the pump outlet can be 0°, 90°, or 180° to meet different connection occasions.

Specifications:

Model ATO-HCP-65-250
Weight 230kg
Size 520*795*330mm
Power 20 hp (15kW)
Phase 3 phase
Input voltage * 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency * 50Hz, 60Hz
Flow (min. flow to max. flow) 17.5m3/h (77 gpm, American system) 25m3/h (110 gpm, American system) 32.5m3/h (143 gpm, American system)
Head (max. head to min. head) 82m (269ft) 80m (262ft) 76.5m (251ft)
Efficiency 39% 50% 52%
Inlet diameter 65mm (2-1/2 inch)
Outlet diameter 65mm (2-1/2 inch)
Installation angle of outlet 0°, 90° and 180°
Nominal diameter of impeller 250mm
Pump type Booster pump
Number of stages Single stage
Motor type Y/Y2 series motor
Motor speed 2900rpm
Impeller material 304/316 stainless steel
Seal material 304 stainless steel, tungsten carbide, fluorine rubber
Inlet max. pressure 1MPa (145 psi)
(NPSH)r 2.5m
Usage Water or liquids compatible with pump component materials.
1. The volume of solid particles should be less than 0.1% in unit volume, and the granularity should be less than 0.2mm.
2. The temperature should be lower than 60℃.
Environment Temperature: <40℃, humidity: <95%, altitude<1000m
Warranty 12 months

 

Horizontal centrifugal pump dimension (unit: mm):

Boundary dimension Base dimension Flange dimension
h H L a A L1 B l b h1 4-Φd1 D D1 n-Φd
280 520 795 100 65 560 330 510 230 100 4-Φ18 Φ185 Φ145 4-Φ18

Horizontal centrifugal pump dimensional drawing

Tips: Centrifugal pump troubleshooting - serious vibration of pump and abnormal noise

  1. If the centrifugal pump foundation is stale
    When vibration occurs, please first check if the anchor bolts of the centrifugal pump are tight. If they are not tightened, it will cause the centrifugal pump to vibrate. Please also consider whether the foundation strength of the foot is sufficient. Sometimes, due to design reasons, the soft foundation can also cause vibration.
  2. Coupling alignment
    Many centrifugal pumps are driven by couplings, and there are many types of couplings. The alignment of the normal three-paw coupling directly affects the normal operation and service life of the coupling, shaft, bearing, and machine seal.
  3. Alignment
    Improper alignment is also a common reason causing vibration. The alignment should be regulated in the specified range according to the standard strictly.
  4. Bearing inspection
    Check if the bearing is correctly installed or damaged.
  5. Adjustment of the rotor central position
    The water pump rotor must be concentric with the stator, otherwise, friction will be generated in the water pump operation, thus causing variation.
  6. Shaft curving and rotor measurement
    If the cause of the variation can not be found externally, the pump can only be disassembled. Please firstly measure and correct the bending of the shaft. After confirming that there is no problem, the rotor will be mounted, and the overall sway and scoring will be measured. If it exceeds the standard, it must be corrected.
  7. Inspection of the dynamic and static balance
    After the centrifugal pump is disassembled, to avoid vibration when the pump is turned on, the impeller should also be conducted with the static balance test.
  8. Influence of external conditions on the water pump
    When all the problems of the pump itself are eliminated, if the vibration problem still cannot be solved, the influence of external conditions on the pump should also be considered. For example, the resonance caused by the natural frequency of the pump base is similar to the vibration frequency, the vibration of the pump caused by the failure of the prime motor, and the strong counterpart used for the connection between the pipeline and the pump will also probably cause abnormal vibration of the pump.
Manual

Horizontal Centrifugal Pump User Manual

Write your own review
*
*
Existing reviews
20hp horizontal centrifugal pump has a long warranty
This is the third time I have purchased this 20hp horizontal centrifugal pump from Inverter.com. They have a long warranty period, so I can use them with confidence. I am very satisfied with their warranty period, and I will continue to purchase products on Inverter.com if necessary.
Adrian Adrian | 8/8/2021 7:29 PM
Was this review helpful? Yes No (0/0)
Load more...
Related products
15 kW Three Phase Solar Pump Inverter

15 kW Three Phase Solar Pump Inverter

GK330-SP3-015
15 kW solar water pump inverter with MPPT, AC output current 32A at 3-phase, RS485 communication, and IP20 protection rating. The water pump solar inverter supports AC and DC input, recommended DC MPPT range (350V, 750V). With a forced cooling fan, the pump inverter can work at (-10°C, 40°C). It is widely applied in irrigation of small farms, greenhouses, domestic use, etc.
$596.69
18.5 kW Three Phase Solar Pump Inverter

18.5 kW Three Phase Solar Pump Inverter

GK330-SP3-018
18.5 kW (25 hp) solar pump inverter, AC 37A output at 3-phase, DC voltage range (280V~750V), works at (-10°C, 40°C). Come with a built-in MPPT controller, a solar pump inverter supporting AC and DC input has intelligent track maximum power point, and automatic regulation of pump flow, which converts DC 450V-750V from the solar panel to 3-phase AC voltage. With automatic sleep performance, solar variable frequency drive improves the reliability of the whole system.
$676.69
20 hp Vertical Centrifugal Pump

20 hp Vertical Centrifugal Pump

ATO-VCP-015KW
20 hp vertical centrifugal pump with a cheap price adopts a single-stage stainless steel impeller and can be operated in series or parallel connection for high flow/ high head water supply or installed in the pipeline for pipeline pressurization. The three-phase vertical pipeline pump has a maximum flow of 65m3/h (286 gpm), a maximum head of 53.5m (176ft), and the same diameter of inlet and outlet 80mm (3 inches), optional input voltage 3 phase AC 220V/240V/380V/415V/480V and optional input frequency 50Hz/60Hz.
$3,668.12
25 hp Horizontal Centrifugal Pump

25 hp Horizontal Centrifugal Pump

ATO-HCP-18d5KW
3 phase centrifugal pump has horizontal structure, 25 horsepower motor power, optional input voltage AC 220V/ 230V/ 380V/ 400V/ 440V/ 460V to 480V, optional input frequency 50Hz/60Hz, maximum flow 29.2m3/h (159 gpm), maximum head 103m (338ft) and same diameter of inlet and outlet 50mm (2 inches). The best 25 hp horizontal centrifugal pump with a low price can be used for cool water pressurization in air conditioners, refrigeration equipment, bathrooms, etc.
From $3,729.94
Inverter.com Reliable Inverters for Today and Tomorrow.
Information
  • About us
  • Shipping & Returns
  • Privacy Notice
  • Conditions of Use
  • Contact us
Support
  • Blog
  • FAQ
  • Download Center
Solution
  • PV Power Generation Solution
  • Power Inverter Solution
  • Frequency Inverter Solution
  • Solar Inverter Solution
Follow us
Powered by inverter.com
Copyright © 2025 inverter.com. All rights reserved.