Close
  • Shopping Cart 0
    You have no items in your shopping cart.
  • Register
  • Log in
  • Wishlist
  • Shopping cart
inverter.com
0
Close
  • Power Inverter
    • Back
    • 12v Inverter
    • 24v Inverter
    • 48v Inverter
    • Car inverter
  • Sine Wave Inverter
    • Back
    • 12v Pure Sine Wave Inverter
    • 24v Pure Sine Wave Inverter
    • 48v Pure Sine Wave Inverter
    • Pure Sine Wave UPS Inverter
  • Solar Inverter
    • Back
    • On Grid Inverter
    • Off Grid Inverter
      • Back
      • Split Phase Off Grid Inverter
    • Micro Inverter
    • Solar Pump Inverter
    • Hybrid Solar Inverter
  • Frequency Inverter
    • Back
    • Single Phase Output Inverter
    • Single to Three Phase Inverter
    • Three Phase Inverter
    • 120v Input Inverter
  • Solar Products
    • Back
    • Solar Charge Controller
      • Back
      • MPPT Solar Charge Controller
      • PWM Solar Charge Controller
    • Solar Water Pump
    • Solar Generator
    • Solar Connector
    • Portable Solar Panel
    • Voltage Converter
    • Centrifugal Pump
      • Back
      • Horizontal Centrifugal Pump
      • Vertical Centrifugal Pump
    • Solar Light
      • Back
      • Solar Flood Light
      • Solar Inground Light
      • Solar Flashlight
  • Generator
    • Back
    • Inverter Generator
    • Wind Turbine
      • Back
      • Horizontal Axis Wind Turbine
      • Vertical Axis Wind Turbine
    • Wind Turbine Charge Controller
Close
  • Home /
  • Solar Products /
  • Centrifugal Pump /
  • Vertical Centrifugal Pump /
  • 30 hp Vertical Centrifugal Pump
30 hp Vertical Centrifugal Pump

30 hp Vertical Centrifugal Pump

$4,567.69
PRICE BREAKS - The more you buy, the more you save
Quantity
5+
10+
50+
Discount
18.5% OFF
19.4% OFF
20.2% OFF
| 2 review(s) | Add your review
30 hp centrifugal pump is a single-stage centrifugal pump, has same diameter of inlet and outlet 100mm (4 inch), maximum flow 130m3/h (572 gpm), maximum head 54m (177ft), optional input voltage AC 220V/ 240V/ 380V/ 400V/ 415V to 440V/ 480V and optional input frequency 50Hz/60Hz. 30 hp vertical centrifugal pump can be used for high flow/ high head water supply, pipeline pressurization, etc.
Delivery date: 6-12 days
SKU: ATO-VCP-022KW
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
increase decrease
  • Overview
  • Reviews
Overview

30 hp vertical centrifugal pump with 130m3/h maximum flow, 54m maximum head, and 100mm diameter of inlet and outlet.

Features:

  1. The centrifugal pump has a vertical structure. The diameter of the inlet and outlet are the same. The inlet and outlet are on the same center line so that the vertical centrifugal pump can be installed in the pipeline like a valve. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. There is no need to dismantle the pipeline system, just lift off the conjunction flat nut of the vertical pump. Then, all the rotor parts can be taken out.
  3. A vertical centrifugal pump can operate in series or parallel connection according to the requirements of flow and head.
  4. A vertical pump can be installed vertically or horizontally according to the requirement of the pipeline system.

Specifications:

Model ATO-VCP-100-200
Weight 268kg
Size 480*475*850mm
Power 30 hp (22kW)
Phase 3 phase
Input voltage * AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency * 50Hz, 60Hz
Flow (min. flow to max. flow) 70m3/h (308 gpm, American system) 100m3/h (440 gpm, American system) 130m3/h (572 gpm, American system)
Head (max. head to min. head) 54m (177ft) 50m (164ft) 42m (138ft)
Efficiency 65% 74% 73%
Inlet diameter 100mm (4 inch)
Outlet diameter 100mm (4 inch)
Installation mode Vertical type or horizontal type
Nominal diameter of impeller 200mm
Pump type Booster pump
Number of stages Single stage
Motor type Y/Y2 series motor
Motor speed 2900rpm
Impeller material 304/316 stainless steel
Seal material 304 stainless steel, tungsten carbide, fluorine rubber
Inlet max. pressure 1MPa (145 psi)
(NPSH)r 4.0m
Usage Water or liquids compatible with pump component materials.
1. The volume of solid particles should be less than 0.1% in unit volume, and the granularity should be less than 0.2mm.
2. The temperature should be lower than 60℃.
Environment Temperature: <40℃, humidity: <95%, altitude<1000m
Warranty 12 months

 

Vertical centrifugal pump dimension (unit: mm):

Boundary dimension Installation dimension Flange dimension
L B H C1*B1 A C2*B2 4-Φd1 ΦD ΦD1 n-Φd
480 475 850 160*220 140 110*170 4-Φ18 Φ220 Φ180 8-Φ18

vertical centrifugal pump dimensional drawing

Tips: How to control the flow of the centrifugal pump?

At present, the centrifugal pump is the most widely used pump product, and it is widely used in the oil and gas, petrochemical, steel, power, food and beverage, chemical, pharmaceutical, and water treatment industries. How to economically and effectively control the output flow of centrifugal pumps has triggered wide discussion. It was once popular to use variable frequency speed control to control the output flow and to cancel the control flow of all control valves. From the current point of view, there are four methods frequently used in the market: outlet valve opening adjustment, bypass valve adjustment, adjustment of impeller diameter, and speed control.

  1. Outlet valve opening adjustment
    In this method, the pump is connected in series with the outlet pipeline regulating valve. The actual effect is like using a new pump system. The large output head of the pump is not changed, but the flow curve is attenuated.
  2. Bypass valve adjustment
    In this method, the valve is connected in parallel with the pump, and its actual effect is like using a new pump system. The large output head of the pump changes, the flow curve characteristics also change, and the flow curve approaches the line shape.
  3. Adjustment of impeller diameter
    This method uses no external component. The flow characteristic curve changes as the diameter changes.
  4. Speed control
    The impeller speed directly changes the flow curve of the pump, and the characteristics of the curve do not change. When the revolving speed decreases, the curve becomes flat, and both the pressure head and mass flow are reduced.

The overall efficiency of the pump system, both the outlet valve adjustment and the bypass adjustment method, increase the pipeline pressure loss and the pump system efficiency is greatly reduced. The impeller diameter adjustment has little effect on the efficiency of the entire pump system, and the speed control method does not affect the system efficiency as long as the speed is not lower than 50% of the normal speed.

Dynamic consumption level
Assume that the output flow of the centrifugal pump is adjusted from 60m3/h to 50m3/h by the above four methods, and the power consumption when the output is 60m3/h is 100% (the pressure head at this time is 70m). how do these flow control means affect the consumption power of the pump?

  1. The power consumption is 94% for the outlet valve opening adjustment, and the consumed power is rather high when the flow is relatively low.
  2. Bypass adjustment. The pressure head of the bypass valve is reduced to 55M. This can only be realized by increasing the flow of the pump. As a result, the power consumption increases by 10%.
  3. Adjust the impeller diameter. After reducing the impeller diameter, the output flow and pressure of the pump reduce accordingly, and the power consumption decreases to 67%.
  4. Control speed. When the revolving speed reduces, both the pump flow and pressure head reduce, and the power consumption decreases to 65%.
Write your own review
*
*
Existing reviews
Would buy again
I was a little worried when I bought such a vertical centrifugal pump for the first time, but the pump worked well after receiving it. Great 30hp pump from this seller, would buy it again.
Seon Garcia | 4/25/2022 12:46 AM
Was this review helpful? Yes No (0/0)
Can you pay for this 30hp vertical centrifugal pump?
Can you pay for this 30hp vertical centrifugal pump?
Joanne Joanne | 11/19/2021 1:38 AM
Was this review helpful? Yes No (0/0)
Responded by inverter.com
Our 30hp vertical centrifugal pump has to be paid first and shipped later.
Load more...
Related products
22 kW Three Phase Solar Pump Inverter

22 kW Three Phase Solar Pump Inverter

GK330-SP3-022
22 kW solar pump inverter, AC 45A output at 3-phase, adapt maximum power point tracking technology, work at (-10°C, 40°C). Support AC and DC input, high efficiency up to 99%, RS485 communication mode. With an IP20 protection rating, the 30 hp pump inverter can automatically sleep at high water levels to achieve Intelligent operation. The water pump solar inverter with a cooling fan has a power factor > 0.99, and vibration less than 5.9m/s².
$703.46
30 kW Three Phase Solar Pump Inverter

30 kW Three Phase Solar Pump Inverter

GK330-SP3-030
Economic 30kW 40 hp solar pump inverter, AC output 60A at 3-phase, DC voltage range (280V, 750V). The solar water pump inverter supporting AC and DC input has multiple-function performance, including auto-sleep function, pump dry protection, low-frequency protection, overload protection, etc. Usually applied for water features and fountains, remote and off-grid locations, and residential water supply.
$1,155.31
30 hp Horizontal Centrifugal Pump

30 hp Horizontal Centrifugal Pump

ATO-HCP-022KW
30 hp horizontal centrifugal pump has a maximum flow of 31m3/h (136 gpm), maximum head 115m (377ft) and same diameter of inlet and outlet 65mm (2-1/2 inch). 3 phase centrifugal pump also has optional input voltage AC 220V/240V/380V/415V /440V to 480V and optional input frequency 50Hz/60Hz, can be used for cool water pressurization in air conditioner, refrigeration equipment, bathroom, etc.
From $4,387.86
40 hp Vertical Centrifugal Pump

40 hp Vertical Centrifugal Pump

ATO-VCP-030KW
40 hp vertical centrifugal pump is a non-self-priming centrifugal pump, has maximum flow 121.6m3/h (535 gpm), maximum head 76m (249ft), the same diameter of inlet and outlet 100mm (4 inches). The low-price 3-phase centrifugal pump also has optional input voltage AC 220V/ 400V/ 460V to 480V and optional input frequency 50Hz/60Hz. It can be used in pipeline pressurization of production line, fire water and air condition system water supply, cooling tower water feeding, and high-rise building pressurized water supply.
From $4,603.69
Inverter.com Reliable Inverters for Today and Tomorrow.
Information
  • About us
  • Shipping & Returns
  • Privacy Notice
  • Conditions of Use
  • Contact us
Support
  • Blog
  • FAQ
  • Download Center
Solution
  • PV Power Generation Solution
  • Power Inverter Solution
  • Frequency Inverter Solution
  • Solar Inverter Solution
Follow us
Powered by inverter.com
Copyright © 2025 inverter.com. All rights reserved.