Close
  • Shopping Cart 0
    You have no items in your shopping cart.
  • Register
  • Log in
  • Wishlist
  • Shopping cart
inverter.com
0
Close
  • Power Inverter
    • Back
    • 12v Inverter
    • 24v Inverter
    • 48v Inverter
    • Car inverter
  • Sine Wave Inverter
    • Back
    • 12v Pure Sine Wave Inverter
    • 24v Pure Sine Wave Inverter
    • 48v Pure Sine Wave Inverter
    • Pure Sine Wave UPS Inverter
  • Solar Inverter
    • Back
    • On Grid Inverter
    • Off Grid Inverter
      • Back
      • Split Phase Off Grid Inverter
    • Micro Inverter
    • Solar Pump Inverter
    • Hybrid Solar Inverter
  • Frequency Inverter
    • Back
    • Single Phase Output Inverter
    • Single to Three Phase Inverter
    • Three Phase Inverter
    • 120v Input Inverter
  • Solar Products
    • Back
    • Solar Charge Controller
      • Back
      • MPPT Solar Charge Controller
      • PWM Solar Charge Controller
    • Solar Water Pump
    • Solar Generator
    • Solar Connector
    • Portable Solar Panel
    • Voltage Converter
    • Centrifugal Pump
      • Back
      • Horizontal Centrifugal Pump
      • Vertical Centrifugal Pump
    • Solar Light
      • Back
      • Solar Flood Light
      • Solar Inground Light
      • Solar Flashlight
  • Generator
    • Back
    • Inverter Generator
    • Wind Turbine
      • Back
      • Horizontal Axis Wind Turbine
      • Vertical Axis Wind Turbine
    • Wind Turbine Charge Controller
Close
  • Home /
  • Solar Products /
  • Centrifugal Pump /
  • Horizontal Centrifugal Pump /
  • 4 hp Horizontal Centrifugal Pump
4 hp Horizontal Centrifugal Pump

4 hp Horizontal Centrifugal Pump

$1,530.16
| 1 review(s) | Add your review
4 hp horizontal centrifugal pump for sale, has optional input voltage AC 220V/230V/340V, 380V/400V/415V, 440V/460V to 480V, optional input frequency 50Hz/60Hz, maximum flow 16.3m3/h (71.8 gpm), maximum head 33m (108ft) and same diameter of inlet and outlet 50mm (2 inches), can be used for high-rise building pressurized water supply, HVAC & refrigeration water circulation, cool water pressurization in air conditioner, etc.
Free shipping
Delivery date: 6-12 days
SKU: ATO-HCP-3000W
*
*
increase decrease
  • Overview
  • Manual
  • Reviews
Overview

4 hp Horizontal Centrifugal Pump with 16.3m3/h maximum flow, 33m maximum head, and 50mm diameter of inlet and outlet.

Features:

  1. The centrifugal pump has a horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. There is no need to dismantle the pipeline system, just lift off the conjunction flat nut of the vertical pump. Then, all the rotor parts can be taken out.
  3. A horizontal centrifugal pump can operate in series and parallel connection according to the requirements of flow and head.
  4. The installation angle of the pump outlet can be 0°, 90°, or 180° to meet different connection occasions.

Specifications:

Model ATO-HCP-50-160
Weight 80kg
Size 370*560*250mm
Power 4 hp (3kW)
Phase 3 phase
Input voltage * AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency * 50Hz, 60Hz
Flow (min. flow to max. flow) 8.8m3/h (38.7 gpm, American system) 12.5m3/h (55 gpm, American system) 16.3m3/h (71.8 gpm, American system)
Head (max. head to min. head) 33m (108ft) 32m (105ft) 30m (98ft)
Efficiency 45% 52% 51%
Inlet diameter 50mm (2 inch)
Outlet diameter 50mm (2 inch)
Installation angle of outlet 0°, 90° and 180°
Nominal diameter of impeller 160mm
Pump type Booster pump
Number of stages Single stage
Motor type Y/Y2 series motor
Motor speed 2900rpm
Impeller material 304/316 stainless steel
Seal material 304 stainless steel, tungsten carbide, fluorine rubber
Inlet max. pressure 1MPa (145 psi)
(NPSH)r 2.3m
Usage Water or liquids compatible with pump component materials.
1. The volume of solid particles should be less than 0.1% in unit volume, and the granularity should be less than 0.2mm.
2. The temperature should be lower than 60℃.
Environment Temperature: <40℃, humidity: <95%, altitude<1000m
Warranty 12 months

 

Horizontal centrifugal pump dimension (unit: mm):

Boundary dimension Base dimension Flange dimension
h H L a A L1 B l b h1 4-Φd1 D D1 n-Φd
210 370 560 80 55 400 250 350 150 80 4-Φ14 Φ165 Φ125 4-Φ18

Horizontal centrifugal pump dimensional drawing

Tips: Optimizing and transforming methods of the centrifugal pump

As everyone knows, during the daily water supply operation of the pump, the water-using period is divided into the peak period and the low peak period according to the different water use times. The amount of water used by the user varies greatly, and the water demand of the system is less than the flow rate of the design condition point most of the time.
However, in the engineering design process, the pump parameters are determined, and pump models are selected according to the most unfavourable working conditions. Due to the incompressibility of water, when the water supply of the pump is greater than the water demand of the system, the pressure of the entire system will increase. At this time, according to the characteristics of the water pump, the operating point of the water pump will move to the side with a rising head and decreasing flow rate. When the flow rate is reduced to a certain value, the pump will deviate from the high-efficiency section. When the flow rate is reduced, the loss of the pipeline system is reduced, and the head required by the system is also continuously reduced so that the head of the water pump is often in an excess state. As a result, not only is the user's water pressure in the over-pressure status, which will bring water using inconvenience to water, but also it will cause energy waste.
To meet the user's water use requirements and economic operation objective, the pump flow rate and head are usually required to be changed to vary the working point. The operating point of the centrifugal pump is determined by the characteristics of the pump and the characteristics of the piping jointly. To realize the economic operation in the pumping station, the operating conditions of the pump must be adjusted. The specific means include:

  • Adjust the throttling valve (change pipeline resistance)
  • Adjust the guiding blade at the entrance (change the blade installation angle)
  • Change the impeller diameter
  • Change the revolving speed of the pump

In this case, the adjustment throttling valve realizes the working condition regulation by changing the pipeline characteristic curve, and the throttling valve achieves this through increasing the pipeline resistance and reducing the flow rate. This adjustment method is uneconomical. Increasing the resistance of the pipeline is equivalent to increasing the pipeline loss. After the flow rate is lowered, the power drop is not obvious. There is also a cavitation problem in the adjustment of the throttling valve of the pump suction end, so this method cannot effectively adjust the flow rate.
The adjustment of the inlet guiding blade is the basic method of the flow rate adjustment of the pump, and the Q-H characteristic curve can be changed to achieve the flow regulation purpose. At this moment, the power is roughly in direct proportion to the flow rate, and the power required to regulate the outlet valve is relatively small.
The adjustment means of changing the impeller diameter cannot be used as a real-time adjustment, so this method has a greater limitation in application. Only the angle and speed changing regulation can be used for real-time adjustment, and the speed changing adjustment has the advantages of wider adjustment range, higher adjustment efficiency, and stronger operability compared with the angle changing regulation. Of course, for large and medium-sized axial and mixed-flow pumps, angle-changing adjustments can be used to adjust the working conditions of the pump. However, for small centrifugal pumps, the working condition point of the water pump is changed by varying the revolving speed of the water pump. Therefore, the centrifugal pump flow adjustment adopts the revolving speed adjustment.

Manual

Horizontal Centrifugal Pump User Manual

Write your own review
*
*
Existing reviews
My need for 4 horsepower horizontal centrifugal pump
Hello, this is my first purchase of a 4hp horizontal centrifugal pump. I am not familiar with him yet. Can you send me some pictures of the 4hp horizontal centrifugal pump before shipment?
Gates Gates | 7/21/2021 3:04 AM
Was this review helpful? Yes No (0/0)
Responded by inverter.com
Ok, no problem.
Load more...
Related products
4 kW Solar Pump Inverter, DC/AC Input to 1ph AC Output

4 kW Solar Pump Inverter, DC/AC Input to 1ph AC Output

GK330-SP1S-004
4 kW solar pump inverter for sale, AC output 13A at 1-phase, and output frequency 0~50/60 (Hz). With the IP20 protection class, the solar pump inverter has RS485 communication mode and vibration is less than 5.9m/s² (0.6 g). The solar pump inverter supporting AC and DC input with the recommended MPPT range (250V, 400V) can work at (-10°C, 40°C). Easy to use and install.
$432.08
4 kW Three Phase Solar Pump Inverter, AC 380V

4 kW Three Phase Solar Pump Inverter, AC 380V

GK330-SP3-004
4 kW solar pump inverter with MPPT tracking technology for sale, AC output current 9A at 3-phase, DC voltage range (280V, 750V). Output frequency 0~400(Hz) and power factor >0.99. The pump inverter supports AC and DC input, storage temperature (-20°C, 60°C) and ambient temperature (-10°C, 40°C). The solar pump inverter is easy to install and operate.
$300.08
4 hp Vertical Centrifugal Pump

4 hp Vertical Centrifugal Pump

ATO-VCP-3000W
4 hp vertical centrifugal pump with cheap price adopts single stage stainless steel impeller, can be operated in series or parallel connection for high flow/ high head water supply, or installed in the pipeline for pipeline pressurization. The three-phase vertical pipeline pump has a maximum flow of 16.3m3/h (72 gpm), maximum head 33m (108ft), same diameter of inlet and outlet 50mm (2 inches), optional input voltage 3 phase AC 230V/240V/400V/415V/480V and optional input frequency 50Hz/60Hz.
$1,358.42
5 hp Horizontal Centrifugal Pump

5 hp Horizontal Centrifugal Pump

ATO-HCP-4000W
3 phase centrifugal pump has horizontal structure, 5 horsepower motor power, optional input voltage AC 220V/ 240V/ 380V/ 415V/ 440V/ 460V to 480V, optional input frequency 50Hz/60Hz, maximum flow 15.3m3/h (67.4 gpm), maximum head 45.8m (150ft) and same diameter of inlet and outlet 50mm (2 inches). The best 5 hp horizontal centrifugal pump with a low price can be used for HVAC & refrigeration water circulation, cool water pressurization in air conditioners, high-rise building pressurized water supply, etc.
$2,083.49
Inverter.com Reliable Inverters for Today and Tomorrow.
Information
  • About us
  • Shipping & Returns
  • Privacy Notice
  • Conditions of Use
  • Contact us
Support
  • Blog
  • FAQ
  • Download Center
Solution
  • PV Power Generation Solution
  • Power Inverter Solution
  • Frequency Inverter Solution
  • Solar Inverter Solution
Follow us
Powered by inverter.com
Copyright © 2025 inverter.com. All rights reserved.