Filters
Close

11 kW Three Phase Solar Pump Inverter

Three phase 11 kW / 15 hp solar pump inverter, converts DC voltage from the solar panels into AC voltage to control three-phase submersible pumps, AC 3 phase 220/400/460V is selectable, can be switched to alternate 3 ph AC input when solar power is not available.
SKU: GK330-011D-3B
Free shipping
Delivery date: 6-12 days
*
$769.60

Three phase DC/AC 11 kW solar pump inverter for irrigation system, built-in maximum power point tracking (MPPT) and work from sunrise to sunset.

Specification

Basics Model GK330-011D-3B
Capacity 11 kW (15 hp)
Weight 11 kg
Product dimension 285*180*208.5 mm
Input Feature Input voltage DC 260~350V, recommend DC 300~350V for 3-phase 220/230/240V motor;
DC 450~750V, recommend DC 600~700V for 3-phase 380/400/415/440/460/480V motor
Three phase 220/380/480V AC (±15%)
Vmp/Voc voltage VMP≥560V, voc≤800V
Rated input current 46.5 A at 220V
26 A at 380/480V
Input frequency 47~63 Hz
Input power of solar panel About 1.5 times the solar pump inverter rated power
Output Feature Output voltage Three phase 0~rated input voltage
Rated output current 45 A at 220V
25 A at 380/480V
Output frequency 50Hz/ 60Hz (output 0-300Hz please contact us)
DC 270-320V corresponds to 0-50Hz for 220VAC, DC 450-550V corresponds to 0-50Hz for 380/480VAC
Control        Control mode SVPWM, SVC
Motor type Asynchronous motor
Speed ratio Asynchronous motor 1:100 (SVC)
Speed control accuracy ±0.2%(SVC)
Speed fluctuation ±0.3%(SVC)
Torque response <20ms (SVC)
Torque control accuracy 10%(SVC)
Starting torque 0.25 Hz / 150% (SVC)
Overload capability 150% of rated current: 1 minute
150% of rated current: 10 seconds
200% of rated current: 1 second
Running control Frequency setting method Digital settingAnalog setting
Pulse frequency setting
Multi-step speed running settingSimple PLC setting
PID setting, MODBUS communication setting
Shift between the set combination and set channel
Operation method Keyboard/ terminal/ communication
Auto-adjustment of voltage Keep a stable voltage automatically when the gird voltage transients
Fault protection Overcurrent, overvoltage, undervoltage, overheating, phase loss, overload, etc.
Special functions for PV water pumps Maximum power tracking, pre-warning at weak light, auto wake up at strong light,
Pre-warning when full water, auto wake up at low water level,
Underload pre-warning and protection of water level sensor,
When pre-warning, the inverter is in stand-by
Environment Environment temperature -10℃~40℃ (environment temperature is among 40℃~50℃; please use it with derating)
Storage temperature -20℃~65℃
Environment humidity Less than 90 % R.H, not exceeding 90% R.H
Altitude, Vibration Below 1000 m, below 5.9m/s² (=0.6g)
Cooling method Forced cooling and natural air cooling
Enclosure rating IP 20
Warranty 18 months

Features

  • Solar pump inverter adopts advanced MPPT control technology, real-time detection of solar panels power voltage, tracking the highest voltage and current, efficiency is as high as 98%.
  • It can enter automatically to sleep mode when the intensity of sunlight is weak, as well as can exit the sleep mode when the intensity of sunlight is becoming strong.
  • Automatic sleep when on high-water level and automatic restart when on low-water level to realize automatic control through water level.
  • Multiple power supply design, power input can be solar energy photovoltaic DC power supply (DC 260~350V, DC 450~750V), can also be single phase or three phase AC power, simple wiring.
  • Smart operation, water level detection and operation panel to prevent overflow, dry pumping.
  • Protect itself in trouble and improve the reliability of whole system.
  • The bypass- AC source which runs automatically when the sun is Not sufficient or absent.

solar pump inverter wiring application

Tips: Why are there fewer solar pump inverter failures in low temperature weather?
1. Winter light is usually not good, solar pump inverter output power is low, solar VFD is running at low load, so the possibility of failure is low.
2. The ambient temperature is low, solar pump inverter operates at low temperature, the reliability of electronic components increases, so it is not easy to malfunction.
Low temperature will not affect the operation of the solar pump inverter. Most components can withstand low temperatures of -25 °C. Moreover, once the inverter is running, when the power component has a current, the temperature will rise and the operating temperature will be greater than the ambient temperature.
Most of the solar pump inverter faults are due to heat, so the inverter should be installed in the place where ventilation and heat dissipation. If you want to have a long life of the inverter, try to choose a inverter with higher power.

Products specifications
Attribute name Attribute value
User Manual

PDFSolar Pump Inverter User Manual

Existing reviews
High quality 11kW three phase solar pump inverter
The 11kW three phase solar pump inverter can works quiet well and have so far surpassed my expectation. It continues to pump even with heavy clouds in the sky, I am very pleased with this 11kW three phase solar pump inverter.
Willow Willow | 6/3/2021 7:13 PM
Was this review helpful? Yes No (0/0)
Write your own review
  • Only registered users can write reviews
*
*
Bad
Excellent